.. partable:: Overview of available keywords related to flow numerics parameters eps :description: Threshold water depth above which cells are considered wet :units: m :default: 0.005 :range: 0.001 - 0.1 eps_sd :description: Threshold velocity difference to determine conservation of energy head versus momentum :units: m/s :default: 0.5 :range: 0.0 - 1.0 hmin :description: Threshold water depth above which stokes drift is included :units: m :default: 0.2 :range: 0.001 - 1.0 oldhu :advanced: :description: Switch to enable old hu calculation :units: - :default: 0 :range: 0 - 1 secorder :advanced: :description: Use second order corrections to advection/non-linear terms based on maccormack scheme :units: - :default: 0 :range: 0 - 1 umin :description: Threshold velocity for upwind velocity detection and for vmag2 in equilibrium sediment concentration :units: m/s :default: 0.0 :range: 0.0 - 0.2